OVERVIEW
NOTE: This boiler was commissioned in 2023–2024 with a water run for testing purposes only and has never been used in production. Essentially new surplus condition.
Fulton Classic Vertical Tubeless Steam Boiler — Model ICS-50, Boiler #PV-11-00, National Board 125873, Year Built 2022. Natural gas fired steam boiler rated at 1,674,000 BTUH output, 1,725 lbs of steam per hour, 150 PSI maximum allowable working pressure. Maximum BTU input at altitude 2,093,000 BTUH. 150 square feet heating surface. Shell thickness 5/16", head thickness 5/8". ASME constructed. Single-phase 230V electrical package. Features Fulton digital burner control system, forced draft burner with blower motor, ASCO water level controls, and complete Fulton-branded auxiliary support package.
Complete system includes: Fulton feedwater unit with vertical multistage centrifugal pump, Fulton water softener system with brine tank, Fulton F-75 flash tank (2021, ASME, NB #1327, 75 PSI @ 400°F), and all associated piping and controls. Assets were commissioned 2023–2024 for testing with water only — never fired in production. Like-new condition throughout.
Ideal for food and beverage processing, distilleries, breweries, commercial laundry, pharmaceutical, laboratory steam, or any facility requiring reliable high-quality low-to-medium pressure steam generation with proven Fulton Classic reliability.
EQUIPMENT SPECIFICATIONS
Boiler Model Information:
Manufacturer: Fulton Boiler Works, Inc.
Manufacturing Location: Pulaski, New York, USA
Product Line: Classic Vertical Tubeless Boiler
Boiler Number: PV-11-00
Model Number: ICS-50
National Board Number: 125873
Year Built: 2022
Type: Vertical Tubeless — Fuel-Fired Steam Boiler
Fuel Type: Natural Gas
ASME Certified: Yes
Performance Ratings:
BTUH Output: 1,674,000 BTUH
Max BTU Input at Altitude: 2,093,000 BTUH
Steam Capacity: 1,725 lbs steam/HR
Maximum Allowable Working Pressure (MAWP): 150 PSI
Heating Surface: 150 SQFT
Construction:
Shell Thickness: 5/16"
Head Thickness: 5/8"
Design: Vertical tubeless pressure vessel
ASME construction and certification
Gas Train Specifications:
Fuel: Natural Gas
Gas Supply Pressure — Minimum: 9" WC
Gas Supply Pressure — Maximum: 13.8" WC
Manifold Gas Pressure — Minimum: ~0.6" WC
Manifold Gas Pressure — Maximum: 4.6" WC
Electrical Specifications:
Boiler Electrical Rating: 230V, 60Hz, 1-Phase, 10 Amps
Controls Rating: 230V, 60Hz, 1-Phase
Burner Motor Rating: 230V, 60Hz, 1-Phase, 10 Amps
Oil Pump Motor: N/A (gas only)
Water Pump Motor: Per feedwater unit specifications
Fulton F-75 Flash Tank:
Model: F-75
Serial Number: F2015398A
Year Built: 2021
National Board Number: NB 1327
Certified By: NFTC
ASME U Stamp: Yes
MAWP: 75 PSI @ 400°F
Min Design Metal Temperature: 50°F @ 75 PSI
KEY FEATURES & BENEFITS
2022 New Surplus — Never Fired in Production:
Built 2022, commissioned 2023–2024 for testing only
Water run completed — never fired in production
Like-new condition throughout
Current generation Fulton Classic technology
Full system ready for immediate installation and startup
Significant value vs. new purchase price
Fulton Classic Vertical Tubeless Design:
Proven Fulton Classic platform — industry standard
Vertical tubeless pressure vessel design
Compact footprint relative to output
Rapid steam generation from cold start
Excellent steam quality
Easy access for inspection and maintenance
ASME certified construction
USA manufactured — Pulaski, New York
High-Output Natural Gas Performance:
1,674,000 BTUH output
1,725 lbs steam per hour
2,093,000 BTUH maximum input capacity
150 PSI MAWP
150 SQFT heating surface
Natural gas fuel
Professional gas train with safety controls
Fulton Digital Burner Control System:
Fulton branded digital burner control panel
Digital display with edit/back/enter navigation
Power, pilot, flame, and main status indicators
Integrated burner management
Modern digital controls vs. older analog systems
Simplified operation and diagnostics
Forced Draft Burner Assembly:
Forced draft combustion system
Blower motor for air supply
Complete burner assembly with gas train
Safety shut-off valves
Flame safeguard supervision
Professional combustion management
Complete Auxiliary Package — All Fulton Branded:
Fulton feedwater unit with vertical multistage centrifugal pump
Fulton water softener system (duplex tanks + brine tank)
Fulton F-75 ASME flash tank (2021, 75 PSI @ 400°F)
All components sourced and matched as a complete Fulton system
ASCO Water Level Controls:
ASCO series water level controls (triple stack)
Manual reset high limit
Low water cutoff protection
Operating level controls
Professional water level management
Safety & Compliance:
150 PSI MAWP ASME construction
Safety relief valve
Low water cutoff (ASCO controls)
Flame safeguard system
Gas pressure monitoring
Manual reset high limit
Emergency shutdown capability
National Board registered: 125873
SYSTEM COMPONENTS
Main Boiler:
Fulton Classic ICS-50
Boiler #PV-11-00, NB 125873
Year Built 2022
1,674,000 BTUH output
1,725 lbs steam/HR
150 PSI MAWP
150 SQFT heating surface
5/16" shell / 5/8" head
Complete with all trim and controls
Burner & Gas Train:
Natural gas forced draft burner assembly
Blower motor (230V, 1PH, 60Hz)
Gas pressure regulator
Safety shut-off valves
Manifold and gas train assembly
Flame safeguard system
Supply pressure: 9–13.8" WC
Manifold pressure: 0.6–4.6" WC
Control Panel:
Fulton Classic branded control panel
Fulton digital burner control (digital display)
Power / Pilot / Flame / Main status indicators
Manual reset button
Boiler on/off switch
Low water reset
230V single-phase electrical
Water Level Controls:
ASCO triple-stack water level control assembly
Low water cutoff (primary)
Operating level control
High limit manual reset
Sight glass level indication
Feedwater Unit:
Fulton branded feedwater unit
Horizontal feedwater tank
Vertical multistage centrifugal feedwater pump (Grundfos-style)
Motor drive assembly
Feedwater supply and return piping
Complete with controls
Water Treatment:
Fulton water softener system
Duplex softener tank configuration
Brine/salt tank
Automatic regeneration control head
Complete pre-treatment for boiler feedwater
Flash Tank:
Fulton Model F-75
Serial F2015398A, Year Built 2021
National Board #NB 1327
ASME U Stamp, Certified NFTC
MAWP 75 PSI @ 400°F
Vertical vessel with inlet/outlet connections
Blowdown flash and condensate recovery
Piping & Valves:
Steam supply piping
Feedwater supply and return piping
Blowdown piping to flash tank
Isolation valves throughout
Safety relief valve
Pressure gauge
All interconnecting piping
SPECIFICATIONS SUMMARY
Manufacturer: Fulton Boiler Works, Inc., Pulaski, NY
Model: ICS-50 (Classic Vertical Tubeless)
Boiler #: PV-11-00
National Board #: 125873
Year Built: 2022
Fuel: Natural Gas
BTUH Output: 1,674,000
Max BTU Input: 2,093,000
Steam Capacity: 1,725 lbs/HR
MAWP: 150 PSI
Heating Surface: 150 SQFT
Shell Thickness: 5/16"
Head Thickness: 5/8"
Gas Supply Pressure: 9–13.8" WC
Manifold Pressure: 0.6–4.6" WC
Electrical: 230V, 60Hz, 1PH, 10A
Burner Motor: 230V, 60Hz, 1PH, 10A
ASME Certified: Yes
Flash Tank: Fulton F-75, 2021, ASME, 75 PSI @ 400°F, NB #1327
Feedwater: Fulton feedwater unit with vertical multistage pump
Water Treatment: Fulton water softener, duplex tanks + brine tank
Condition: New Surplus — Never Fired in Production
ADDITIONAL INFORMATION
Condition: New Surplus — Never Fired in Production
Year Built: 2022
Commissioned: 2023–2024 (water run testing only, never fired)
Manufacturer: Fulton Boiler Works, Inc.
Location: Pulaski, New York, USA
Model: ICS-50
Boiler Number: PV-11-00
National Board Number: 125873
Type: Classic Vertical Tubeless Steam Boiler
Fuel: Natural Gas
BTUH Output: 1,674,000
Max BTU Input at Altitude: 2,093,000
Steam Capacity: 1,725 lbs/HR
MAWP: 150 PSI
Heating Surface: 150 SQFT
Shell: 5/16" thickness / Head: 5/8" thickness
Gas Supply Pressure: 9" WC min / 13.8" WC max
Manifold Gas Pressure: 0.6" WC min / 4.6" WC max
Electrical: 230V, 60Hz, 1-Phase, 10 Amps
Controls: Fulton digital burner control panel
Water Level Controls: ASCO triple-stack assembly with manual reset
ASME Certified: Yes
WHAT'S INCLUDED:
Fulton ICS-50 Classic vertical tubeless steam boiler (2022) — complete with all trim and controls
Fulton digital burner control panel
Forced draft burner assembly with blower motor
ASCO water level controls (triple stack)
Fulton feedwater unit with vertical multistage centrifugal pump
Fulton water softener system (duplex tanks + brine tank)
Fulton F-75 ASME flash tank (2021, NB #1327, 75 PSI @ 400°F)
All associated piping, valves, and instrumentation
INSTALLATION NOTES:
Natural gas supply required — 9 to 13.8" WC inlet pressure
230V single-phase electrical service required
Never fired in production — minimal preparation required for startup
Professional boiler startup and commissioning recommended
* Manufacturer: Fulton Boiler Works, Inc.
* Manufacturing Location: Pulaski, New York, USA
* Product Line: Classic Vertical Tubeless Boiler
* Boiler Number: PV-11-00
* Model Number: ICS-50
* National Board Number: 125873
* Year Built: 2022
* Fuel Type: Natural Gas