Your Cart
You don't have any items in your cart.

USED 2019 FULTON VSRT60

Overview
Type:
Boilers
Manufacturer:
FULTON
Model:
VSRT60
Year:
2019
Stock #:
BSF60HP269
Description

OVERVIEW
Fulton VSRT60 Vertical Spiral Rib Tubeless Steam Boiler - National Board Number 1064, Serial Number F10111581A, Year Built 2019. Professional-grade natural gas-fired vertical spiral rib tubeless steam boiler featuring 2,008,500 BTU/HR output capacity with 2,070 lbs/hr steam generation at 150 PSI maximum allowable working pressure and 116 square feet heating surface. Complete packaged system includes Fulton integrated control panel with Local 399 union certification, cyclone blower for combustion air, VFD drive control panel, and 460V three-phase electrical systems. Built to ASME standards with innovative vertical spiral rib tubeless design for superior heat transfer and efficiency. Features 3/8" shell thickness, 3/8" head thickness, stainless steel construction, and modern digital monitoring systems. Gas supply pressure range: 4" WC minimum to 13.8" WC maximum. Manifold gas pressure range: -1.9" WC minimum to -5.5" WC maximum. Complete with all safety trim and controls installed. Ideal for commercial buildings, light industrial facilities, institutional applications, or any operation requiring compact, efficient steam generation with proven Fulton vertical spiral rib tubeless technology and space-saving design.
 
EQUIPMENT SPECIFICATIONS
 
Boiler Model Information:

Manufacturer: Fulton
Product Line: Vertical Spiral Rib Tubeless Boiler
Model Number: VSRT60
Serial Number: F10111581A
National Board No: 1064
Year Built: 2019
Configuration: Vertical spiral rib tubeless steam boiler
Type: Natural gas-fired
Horsepower: 60 BHP

 
Performance Ratings:

BTU Output: 2,008,500 BTU/HR
Boiler Horsepower: 60 BHP
Steam Capacity: 2,070 lbs/hr
Heating Surface: 116 sq. ft.
Maximum Allowable Working Pressure: 150 PSI
Shell Thickness: 3/8"
Head Thickness: 3/8"
Fuel Type: Natural Gas

 
Gas Supply Specifications:

Gas Supply Pressure Min: 4" WC (Water Column)
Gas Supply Pressure Max: 13.8" WC
Manifold Gas Pressure Min: -1.9" WC
Manifold Gas Pressure Max: -5.5" WC

 
Electrical Specifications:

Boiler Electrical Rating: 460V, 60 Hz, 3-Phase
Burner Motor Rating: 460V, 60 Hz, 3-Phase
VFD Rating: 460V, 60 Hz, 15.4 Amps
Controls Rating: 60V, 60 Hz

 
Physical Dimensions:

Overall Length: 66"
Overall Width: 66"
Overall Height: 100"
Weight: 5,500 lbs
Recommended Packaging: Custom Pallet

 
Additional Components:

Cyclone Blower: Induction air intake system
VFD Drive: Variable frequency drive control panel
Control Panel: Local 399 union certified
Origin: USA

 
KEY FEATURES & BENEFITS
 
Fulton Quality Manufacturing:

Premium USA boiler manufacturer
2019 year of manufacture
Vertical Spiral Rib Tubeless series
National Board certified (1064)
Heavy-duty commercial construction
Professional installation quality
Nearly new condition
Modern manufacturing standards

 
High-Efficiency Performance:

60 boiler horsepower rating
2,008,500 BTU/HR output
2,070 lbs/hr steam generation
116 sq. ft. heating surface
150 PSI maximum working pressure
Natural gas fuel efficiency
Compact vertical design
Continuous duty rated

 
Vertical Spiral Rib Tubeless Design:

Innovative spiral rib technology
Tubeless construction eliminates tube maintenance
No tube bundle to clean or replace
Vertical orientation saves floor space
Enhanced heat transfer surfaces
Spiral rib configuration maximizes efficiency
Faster steam generation
Better thermal efficiency
Reduced maintenance requirements
Longer service life
Improved water circulation

 
Advanced Combustion System:

Cyclone blower for combustion air
Induction air intake system
Variable frequency drive (VFD) control
Optimized air/fuel ratio
Enhanced combustion efficiency
Reduced emissions
Professional burner management
Modern control technology

 
Digital Control Systems:

Fulton integrated control panel
Local 399 union certified installation
VFD drive control panel
Real-time monitoring
Diagnostic capabilities
Temperature and pressure monitoring
User-friendly operation
Professional-grade components

 
Heavy-Duty Construction:

3/8" shell thickness
3/8" head thickness
Stainless steel construction
Corrosion-resistant materials
Robust design
Long service life
Minimal maintenance
Industrial-grade quality

 
Nearly New Condition:

2019 year of manufacture
Modern design and technology
Recent construction standards
Minimal operating hours
Excellent condition
Current safety standards
Up-to-date engineering
Extended service life remaining

 
Safety & Compliance:

150 PSI ASME design pressure
National Board certified (1064)
Multiple safety interlocks
Safety relief valve protection
Low water cutoff protection
Flame safeguard system
Code-compliant installation
Professional engineering
Local 399 union certified

 
SYSTEM COMPONENTS
 
Main Boiler:

Fulton Model VSRT60
Serial Number F10111581A
National Board No: 1064
Year 2019 manufacture
Vertical spiral rib tubeless design
60 BHP capacity
116 sq. ft. heating surface
150 PSI MAWP
Stainless steel construction
Complete with all trim

 
Burner System:

Natural gas burner
Power burner design
Forced draft combustion
Modulating control capability
Gas train components
Safety shut-off valves
Flame safeguard system
Professional installation

 
Combustion Air System:

Cyclone blower assembly
Induction air intake design
Variable frequency drive control
Air damper controls
Combustion air ducting
Professional installation
Optimized air delivery

 
Control Systems:

Fulton integrated control panel
VFD drive control panel
Local 399 union certified
Burner management system
Flame safeguard controls
Operational diagnostics
Temperature controls
Pressure monitoring
Safety interlocks

 
Electrical Components:

460V three-phase power supply
60 Hz frequency
VFD rated 15.4 amps
60V control systems
All wiring and connections
Disconnect provisions
Circuit protection
Professional installation

 
Safety & Instrumentation:

Low water cutoff protection
Safety relief valve
Pressure gauge
Temperature sensors
Water level controls
Gas pressure switches
Flame supervision
Emergency shutdown capability

 
Water System:

Feedwater connections
Water level controls
Feedwater valves
Piping connections
Blowdown valve
Drain connections
Level indication
Low water protection

 
Gas System:

Gas pressure regulator
Manual gas valve
Safety shut-off valves
Gas pressure switches
Inlet connection
Manifold pressure monitoring
Safety interlocks
Professional gas train

 
SPECIFICATIONS SUMMARY
 
Boiler:

Manufacturer: Fulton
Model: VSRT60
Serial No: F10111581A
National Board: 1064
Year: 2019
Type: Vertical spiral rib tubeless steam boiler
Fuel: Natural Gas
Horsepower: 60 BHP
Output: 2,008,500 BTU/HR
Steam: 2,070 lbs/hr
Heating Surface: 116 sq. ft.
Max Pressure: 150 PSI
Shell: 3/8" thickness
Head: 3/8" thickness
Origin: USA
Construction: Stainless steel

 
Gas Supply:

Supply Pressure Min: 4" WC
Supply Pressure Max: 13.8" WC
Manifold Pressure Min: -1.9" WC
Manifold Pressure Max: -5.5" WC
Fuel Type: Natural Gas

 
Electrical:

Voltage: 460V
Phase: 3-Phase
Frequency: 60 Hz
VFD: 15.4 Amps
Controls: 60V

 
Physical:

Length: 66"
Width: 66"
Height: 100"
Weight: 5,500 lbs
Configuration: Vertical
Design: Spiral rib tubeless
Mounting: Floor-mounted
Finish: Stainless steel

 
Additional Components:

Cyclone Blower: Included
VFD Drive Panel: Included
Control Panel: Local 399 certified
Packaging: Custom pallet recommended

 
ADDITIONAL INFORMATION

Condition: Used - 2019 Manufacture, Excellent Condition

Manufacturer: Fulton

Product Line: Vertical Spiral Rib Tubeless Boiler

Model: VSRT60

Serial Number: F10111581A

National Board Number: 1064

Year Built: 2019

Fuel Type: Natural Gas

BTU Output: 2,008,500 BTU/HR

Boiler Horsepower: 60 BHP

Steam Generation: 2,070 lbs/hr

Heating Surface: 116 square feet

Maximum Allowable Working Pressure: 150 PSI

Shell Thickness: 3/8 inches

Head Thickness: 3/8 inches

Gas Supply Pressure: 4" WC minimum to 13.8" WC maximum

Manifold Gas Pressure: -1.9" WC minimum to -5.5" WC maximum

 
Electrical Requirements:

Boiler: 460V, 3-Phase, 60 Hz
Burner Motor: 460V, 3-Phase, 60 Hz
VFD: 460V, 60 Hz, 15.4 Amps
Controls: 60V, 60 Hz

 
Physical Dimensions:

Overall Length: 66 inches
Overall Width: 66 inches
Overall Height: 100 inches
Total Weight: 5,500 lbs

 
Packaging Requirements:

Recommended: Custom Pallet
Rigging: Professional rigging required
Transport: Specialized equipment needed

 
Control System: Fulton integrated control panel with VFD drive - Local 399 certified
Combustion Air System: Cyclone blower with induction air intake
 
Safety Features:

Low water cutoff protection
Safety relief valve
Flame supervision system
Multiple safety interlocks
Emergency shutdown capability
Pressure relief protection
Gas pressure monitoring
Professional safety controls
Local 399 union certified installation

 
Installation Requirements:

Professional installation required
Foundation specifications per manufacturer
Adequate clearances per code requirements
Professional rigging and placement
Electrical hookup by licensed electrician
Gas connection by licensed professional
Professional commissioning recommended

 
Features:

Fulton Vertical Spiral Rib Tubeless Boiler design
2019 year of manufacture - nearly new condition
60 boiler horsepower rating
2,008,500 BTU/HR output capacity
2,070 lbs/hr steam generation
116 square feet heating surface
150 PSI maximum working pressure
Natural gas-fired for efficient operation
Vertical spiral rib tubeless design
No tube bundle to clean or replace
Spiral rib configuration maximizes heat transfer
Tubeless construction eliminates tube maintenance
Compact vertical footprint saves floor space
Heavy-duty 3/8" shell thickness
Robust 3/8" head thickness
Stainless steel construction for corrosion resistance
National Board certified (1064)
ASME construction and certification
Cyclone blower for combustion air
Induction air intake system
Variable frequency drive (VFD) control
VFD rated 15.4 amps
Fulton integrated control system
Local 399 union certified control panel
Real-time monitoring and diagnostics
Low water cutoff protection
Safety relief valve protection
Flame safeguard system
All safety trim and controls installed
460V three-phase electrical package
60V control systems
Professional-grade components throughout
Complete packaged system
Ready for natural gas connection and startup
2019 manufacture - excellent condition
Cyclone blower with VFD drive included
Local 399 union certified installation
Professional-grade commercial/industrial construction
Dimensions: 66"L x 66"W x 100"H
Weight: 5,500 lbs
Custom pallet packaging recommended

Specifications

* Manufacturer: Fulton
* Model Number: VSRT60
* Serial Number: F10111581A
* National Board No: 1064
* Year Built: 2019

Loading...
Loading...
Loading...