Pressurized Deaerators

Pressure & Temperature Ratings:

MAX AWP 50 PSI AT 650°F
AWP = Allowable Working Pressure

This tank is rated for a maximum of 50 PSI at 650°F.
This is higher than normal operating conditions, which ensures safety margin.
MIN DMT -20°F AT 50 PSI
DMT = Design Metal Temperature

The vessel can safely handle -20°F metal temperature while still holding 50 PSI.
This ensures toughness at cold conditions (fracture resistance).