Your Cart
You don't have any items in your cart.

Industrial Deaerator (DA) Tank System with Multi-Pump Configuration

Overview
Stock #:
TTSU230
Description

Overview

This industrial deaerator tank system provides essential feedwater treatment for steam boiler operations. Featuring a robust insulated pressure vessel with four independent boiler feed pumps, this system ensures continuous, oxygen-free water supply to your boilers. The complete package includes LT Industries control panel, multiple feedwater lines with manual isolation valves, and comprehensive safety systems. Currently installed and operational in an active facility, demonstrating proven reliability and professional craftsmanship.

Design and Performance

Tank Type: Horizontal Cylindrical Deaerator

Configuration: Multi-pump redundant system

Feedwater Pumps: 4 Independent units

Control System: LT Industries BFT-1 Panel

Piping: Color-coded with flow direction markers

Insulation: Full tank insulation with protective white coating

Mounting: Elevated steel framework

Safety Features: Multiple relief valves with chain operators

Installation Status: Currently operational

System Components

Primary Equipment

Deaerator Tank: Horizontal pressure vessel with inspection ports

Pump Configuration: Four (4) vertical feedwater pumps

Control Panel: BFT-1 with individual pump controls

Valve System: Manual isolation valves on each line

Safety Valves: Multiple pressure relief points

Support Structure: Heavy-duty steel framework

Instrumentation: Pressure gauges and monitoring points

Control System Features

Panel Model: LT Industries BFT-1

Pump Controls: BFP-1, BFP-2, BFP-3, BFP-4

Control Type: Individual start/stop switches

Indicators: Status lights for each pump

Protection: Industrial-grade enclosure

Mounting: Wall-mounted at operator height

Piping Configuration

Feedwater Lines: Four (4) vertical lines

Valve Type: Manual gate valves

Line Marking: Yellow directional flow indicators

Headers: Properly sized distribution manifolds

Connections: Flanged for easy maintenance

Layout: Organized for optimal access

Technical Specifications

Number of Pumps: 4 independent units

Control Voltage: Standard industrial voltage

Piping Material: Carbon steel with appropriate ratings

Insulation Type: Thermal insulation with protective jacket

Safety Compliance: ASME code construction

Pressure Rating: Suitable for standard boiler systems

Temperature Rating: High-temperature operation capable

Key Features

Redundancy: Four-pump design ensures continuous operation

Control Flexibility: Individual pump control for maintenance

Safety Systems: Multiple relief valves and pressure monitoring

Professional Installation: Properly supported and piped

Easy Maintenance: Accessible valves and components

Proven Design: Currently in active service

Complete Package: All components included

Ideal Applications

Multi-boiler plants
Industrial steam systems
Process steam facilities
Power generation
Manufacturing plants
Hospital steam systems
University central plants
Food processing facilities
Any facility requiring reliable deaerated feedwater

Benefits

Continuous Operation: Multi-pump redundancy prevents downtime

Oxygen Removal: Protects boilers from corrosion

Flexible Control: Individual pump operation

Safety First: Multiple pressure relief points

Professional Quality: Industrial-grade components throughout

Proven Performance: Currently operational

Complete System: Turnkey installation

Easy Integration: Standard connections and controls

System Advantages

Operational Benefits

Eliminates dissolved oxygen from feedwater
Prevents boiler corrosion and pitting
Improves overall system efficiency
Reduces chemical treatment requirements
Extends boiler life
Provides consistent water temperature
Enables scheduled pump maintenance without shutdown

Design Benefits

Compact footprint for space efficiency
Elevated design for gravity feed
Multiple pump redundancy
Easy operator access to controls
Clear valve identification
Professional piping layout
Robust construction for long life

Installation Features

Current Status: Installed and operational

Mounting: Structural steel support system

Access: Walk-around design for maintenance

Connections: Standard flanged connections

Control Location: Ergonomic panel placement

Safety Access: Chain-operated relief valves

Documentation: Installation follows industry standards

Maintenance Considerations

Individual pump isolation for service
Accessible valve locations
Clear component identification
Standard replacement parts
Multiple access points
Organized piping layout
Professional installation quality

Safety & Compliance

ASME code construction standards
Multiple pressure relief valves
Proper vessel support system
Safety valve accessibility
Clear operational markings
Industrial-grade components
Professional installation standards
Comprehensive pressure monitoring

Additional Information

Condition: Operational system

Installation Quality: Professional grade

System Completeness: All components included

Control Features: Individual pump control

Redundancy Level: Four independent pumps

Maintenance Access: Excellent

Space Requirements: Compact design

Integration: Standard connections

System Details

This complete deaerator system demonstrates professional installation and design, featuring:

Four independent boiler feed pumps for ultimate reliability
Individual pump controls allowing maintenance without system shutdown
Comprehensive safety systems with multiple relief valves
Professional piping with clear identification
Currently operational proving system reliability

 
The multi-pump configuration ensures your boiler system never lacks properly treated feedwater, while the individual controls provide maximum operational flexibility.

Loading...
Loading...
Loading...