USED SIGMA INTERNATIONAL BAX35700

Pennsylvania, United States
Asking Price
USD $1,195.00
1 available
73Listings|1Follower
Overview
Pumps / Aspirators

Sigma spectrum 6.05.14 Infusion pump with wireless B/G battery

Model# BAX35700

Certified with 1 year warranty

The Baxter Sigma Spectrum 6.05.14  Infusion Pump comes Patient Ready with AC adapter, pole clamp and wireless B/G  battery. Software version 6.05.14

The SIGMA Spectrum 6.05.14 Infusion System reduces errors in programming IV infusion. The SIGMA Spectrum is easy to use with automatic start-up of the Master Drug Library (MDL) and capability to integrate infusion data into the Electronic Medical Record (EMR).

The SIGMA Gateway provides bi-directional communication capabilities to the SIGMA Spectrum through a hospital’s existing b/g wireless network. This allows delivery of the MDL to an entire fleet of pumps as well as continuous Quality Improvement (CQI) reports to the SIGMA Gateway.

Features:

Automatic MDL start-up when machine powers on

Automatic drug library updates through wireless searching of updates, downloads and installs

Lightweight, compact design promotes patient mobility

Bright color screen

Lithium-ion battery pack

 

 

The SIGMA Spectrum Infusion System is redefining smart technology with Second Generation software to help prevent pump-related medication errors

Specs
Dimensions
5.6″ x 4.25″ x 1.75″
Weight
2.5 lbs., including char

Item Name: Spectrum, Baxter calibrated Manufacturer: Sigma International Equipment Category: Infusion Pump Mounting/Use: Pole-Mounted Therapy Type: Large Volume Size: 5.6″ x 4.25″ x 1.75″ Weight: 2.5 lbs., including char
Dimensions:

Standard Battery:

Without IV Pole Clamp: 5.8″ x 4.2″ x 2.5″ (147 mm x 107 mm x 63.5 mm).

With IV Pole Clamp: 5.8″ x 6.4″ x 4.7″ (147 mm x 163 mm x 119 mm).

Wireless Battery Module:

Without IV Pole Clamp: 6.3″ x 4.2″ x 2.5″ (160 mm x 107 mm x 63.5 mm).

With IV Pole Clamp: 6.3″ x 6.4″ x 4.7″ (160 mm x 163 mm x 119 mm).

Weight:

Standard Battery:

Without IV Pole Clamp: 25 oz ± 1 oz (708 grams ± 28 grams).

With IV Pole Clamp: 33.5 oz ± 1 oz (950 grams ± 28 grams).

Wireless Battery Module: Less than or equal to 0.75 lb (340 grams).

Battery:

Standard Battery:

Lithium Ion, 1800 mA/h, 7.2V nominal. SIGMA Part Number, 35702.

Pump operating time on battery power is at least 8 hours at 125 ml/hour with the backlight on (new battery).

12 hour recharge time.

Charging occurs if AC Power Adaptor is plugged in whether pump is ON or OFF.

Wireless Battery Module:

Lithium Ion, 1800 mA/h, 7.2V nominal. SIGMA Part Number, 35083.

Capacity 4 hrs (500 mL) at 125 mL/hour at the highest backlight settings.

12 hour recharge time.

Charging occurs if AC Power Adaptor is plugged in whether pump is ON or OFF.

Pump Characteristics and Flow Rate Accuracy:

Linear peristaltic mechanism.

0.5 to 999 mL/hour flow range in 0.1 mL/hour increments from 0.5 to 99.9 mL/hour and 1 mL/hour increments thereafter.

Volumetric accuracy (based on volume collected over one hour) using standard Hospira, Baxter.

± 5% from 2 to 800 mL/hour, greater than 800 mL/hour ± 10% for Hospira ± 5% from 2 to 999 mL/hour for Baxter, 0.5 to 1.9 m/hour ± 0.1 mL. Total volume up to 9 liters (Hospira) or 12 liters (Baxter).

KVO – Keep vein open rate of either 1 mL/hour or the actual rate, whichever is lower, at infusion complete alarm.

Maximum pump pressure – 36 PSI (which can never be obtained with operational occlusion alarm limits).

Wireless Network Interface:

Standard: IEEE 802.11b.

Frequency: 2.4 GHz.

Data Rate: Up to 11 Mbps with automatic fallback.

Modulation: CCK (11/5 Mbps), DQPSK (2 MBPS), DBPSK (1 MBPS).

Transmit Power: 16 dBm typical.

Receiver Sensitivity: -82 dBm at 11 Mbps.

Wireless Security:

WEP (Wired Equivalent Privacy): 64/128-bit encryption (RC4).

WPA/WPA2/802.11i:

128-bit TKIP/CCMP encryption.

802.1 x EAP authentication:

LEAP (WEP only), PEAP, TTLS.

GTC, MD5, OTP, PAP, CHAP, MSCHAP, MSCHAPc2, TTLS-MSCHAPv2.

Pre-shared key mode (PSK).

Environmental Limits:

With Standard Battery:

Operating Temperature: 60 to 90 °F (15.6 to 32.3 °C), 20 to 90% relative humidity non-condensing.

Storage Temperature: -4 to 120 °F (-20 to 49 °C), 10 to 90% relative humidity non-condensing.

With Wireless Battery Module:

Operating Temperature: 60 to 80 °F (15.6 to 26.7 °C), 20 to 90% relative humidity non-condensing.

Storage Temperature: -4 to 120 °F (-20 to 49 °C), 10 to 90% relative humidity non-condensing.

Display: Full color, HRTFT, 240 x 270, LED front-lit, 0.2235 mm x 0.2235 mm dot pitch.

Alarms and Alerts:

Air-In-Line: Dual beam ultrasonic detector alarms for large bubbles but allows smaller bubbles to pass. Detects air bubbles greater than 1″ (≈ 125 μL Hospira, ≈ 140 μL Baxter), will alarm if greater than 1 mL of air in 15 min., less than 50 μL bubbles are omitted in the summation of the 1 mL.

Audio: Speaker actuated audio alarm, low, medium, and high levels selected through the configurations screen.

Battery Missing: Pump does not detect battery attached.

Depleted Battery: Pump stops running, alarms for 3 minutes.

Dose Rate Limit Exceeded: The pump will run with a soft dose rate exceeded after a double confirmation, it will not run with a hard dose rate exceeded, rates must be reset within hard limits.

Downstream Occlusion: Automatic restart occurs after the downstream occlusion is cleared. Actuation can be set to Low, 6 ± 4 PSI, Medium, 13 ± 6 PSI, or High, 19 ± 9 PSI.

Inactivity: Actuates after the pump has been inactive for 2 minutes.

Infusion Complete: Occurs when the VTBI reaches zero, at which time a KVO rate begins (the previous running rate or 1 mL/hour, whichever is lower).

In Stop: Load set.

In Stop: Open side clamp.

In Stop: Push run.

Low Battery: Less than 30 minutes of battery power remain.

Shut Door.

Side Clamp Closed: Pump stopped.

System Error.

Upstream Occlusion.

Very Low Battery: Less than 15 minutes of battery power remain.

Timekeeping: Real time clock, battery backed, 10 year life.

Logging Memory:

24 hour memory of all set up screens except for ramp/taper modes that are maintained permanently.

Separate pump and drug library history logs, minimum of 96 hours each under extensive logging intensive operating conditions.

AC Power:

AC Power Adaptor, low profile, covers only one outlet, Medical Grade (EN60601-1-2), Input: 100 V-AC to 240 V-AC, 50 to 60 Hz/200 mA, Output: 9 V-DC / 800 mA, short circuit protected, cord length 3.0 m (~ 9.75′). Use only SIGMA part number 55079 or equivalent.

The SIGMA Spectrum Infusion Pump is classified according to Medical Electrical Equipment standards as:

Class II Equipment.

Type BF Applied Part.

Continuous Operation.

External Interfaces: RS-232 (RTX and CTS only), IrDA (SIR Encoding Protocol. Supports IrOBEX). Additional Asynchronous Serial Port Expansion bus available at battery terminals. Software upgrades may be performed through external RS-232 or IrDA ports.

Standards:

IEC60601-1 including collateral standards; Third Party Notified Body Testing (Reference Electromagnetic Compatibility Tables).

IrDA Serial Infrared Physical Layer Link Specification v1.4(IrPHY), IrDA Serial Infrared Link Access Protocol v1.1 (IrLAP) and IrDA Serial Infrared Link Management Protocol v1.1 (IrLMP), IrDA Tiny TP v1.1.

Wireless – 802.11b.
Weight: 0.00 lbs
Dimensions: 0.00 × 0.00 × 0.00 in