Your Cart
You don't have any items in your cart.
Used

Medrad Stellant CT Injection System and WorkStation

California, United States
Asking Price
USD $28,000.00
1 available
1,101Listings|1Follower
Overview
Medical Imaging - Other

Enhanced Protocol Management

Storage and recall of up to 250 protocols.

Designed for complex CTA and Cardiac CT protocols.

Creates a tight contrast bolus.

Enables precisely timed contrast delivery.

Ability to add Certegra P3T 2.0 technology to drive personalized patient protocol standardization through new capabilities, including presets for radiologist-preferred protocols and the ability to save and recall P3T software protocols.

Dual Syringe Utilization Benefits

Uniform Enhancement

Clinical benefits of injecting contrast and saline at different ratios to visualize the whole heart. Clinical research has shown that simultaneous injection of contrast and saline, in user-selected ratios, can.

SProvide more uniform attenuation of the right and left ventricles.

Minimize artifacts by achieving proper attenuation levels.

Visualize the right coronary arteries and right ventricles in a single study by achieving more uniform attenuation.

Medrad Stellant Specifications

Injection Specifications

Flow Rate: 0.1 to 10 mL/sec on 0.1 mL increments

Volume: 1 mL to syringe capacity in 1 mL increments

Programmable Pressure Limit: 200 mL syringe: 325 psi, 2241 kPa

Scan Delay: 0-300 seconds (5 minutes) in 1 second increments

Pause: 1-900 seconds (15 minutes) in 1 second increments

Hold: Maximum HOLD time is 20 minutes

Syringes (Volume Capacity): 200 mL sterile disposable syringe

Maximum Number of Phases: 6

Maximum Number of Protocols: 250

General Specifications

Electrical Requirements: 100-240 VAC, 50/60 Hz, 300 Volts-AMPs

Syringe Heat Maintainer Range: 95 degrees F ± 9 degrees; 35 degrees C ± 5 degrees

Head Mounting Options: Overhead Counterpoise System of Floor Pedestal (Floor Pedestal includes an Integral IV Pole)

DualFlow: Simultaneous Injection of Contrast and Saline

Medrad XDS Extravasation Detection System: Extravasation Detector; Extravasation Detector Device

Certegra P3T Cardiac Application: Patient-specific Injection Protocols for Cardiac CTA

Certegra P3T Abdomen Application: Abdominal Protocol Optimization Software

Certegra P3T PA Application: Pulmonary Angiography Protocol Optimization Software

Mechanical Specifications

Dual Injector Head

Depth: 14.5" (36.8 cm)

Base Unit

Depth: 8.8" (22.2 cm)

Certegra Workstation (CWS)

Depth: 10.2" (30.0 cm)

Specs

Height: 6.1" (15.5 cm)
Width: 12.1" (30.7 cm)
Weight: 17.9 lb (8.1 kg) (Without Syringe)
Height: 11.5" (29.2 cm)
Width: 11.0" (27.9 cm)
Weight: 13.6 lb (6.2 kg)
Height: 13.5" (34.2 cm)
Width: 15.8" (40.0 cm)
Weight: 17.6 lb (8.0 kg)