Your Cart
You don't have any items in your cart.
Used

Used 2019 SPX Marley AquaTower AQ492G1BAF Cooling Tower – 28 Nominal Tons, 2 HP Fan, Crossflow Design

Illinois, United States
3,035Listings|343Followers
Overview
Cooling Towers

Manufacturer Information
Manufacturer: SPX Cooling Technologies Brand: Marley Product Line: AquaTower Model: AQ492G1BAF Equipment Type: Industrial / Commercial Cooling Tower Year Built: 2019 Condition: Used
SPX Cooling Technologies manufactures Marley cooling towers and heat rejection equipment for commercial HVAC, industrial processing, and recirculating cooling-water systems.
Marley AquaTower cooling towers are factory-assembled, induced-draft crossflow units designed to reject heat from circulating water through evaporative cooling.
This 2019 Marley AquaTower Model AQ492G1BAF features an approximately 28 nominal ton cooling capacity, a 36-inch diameter fan, 2 HP motor, PVC film fill, integral louvers, and drift eliminators.
Description
Available for sale is a used 2019 SPX Marley AquaTower cooling tower, Model AQ492G1BAF, designed for commercial and industrial heat rejection applications.
Marley engineering data for the 492G configuration lists approximately 28 nominal tons of cooling capacity, based on the following operating conditions:

Hot water temperature: 95°F

Cold water temperature: 85°F

Entering wet-bulb temperature: 78°F

Water circulation rate: 3 GPM per nominal ton

At these nominal rating conditions, the corresponding circulating water flow is approximately 84 GPM.
The cooling tower features a factory-assembled induced-draft crossflow design. This configuration draws air through the cooling tower fill while circulating water moves downward through the heat transfer media.
The unit includes PVC film fill, designed to provide surface area for evaporative heat transfer, along with integral louvers and drift eliminators to help manage airflow and minimize water droplet carryover.
Air movement is provided by a 36-inch diameter fan driven by a 2 HP motor, rated 208–230/460V, 3-phase, 60 Hz, at 1,750 RPM.
The cooling tower includes 4-inch inlet and outlet connections for integration into compatible recirculating cooling-water systems.
Overall dimensions are approximately 72" long x 48" wide x 90" tall, providing a compact footprint for the stated nominal cooling capacity.
Manufactured in 2019, this Marley AquaTower is identified by Serial No. 10183156-A1.
Potential applications include HVAC cooling, industrial process cooling, heat exchanger systems, compressor cooling, chiller condenser-water systems, and other compatible commercial or industrial heat rejection applications.
Specifications

Specification

Details

Manufacturer

SPX Cooling Technologies

Brand

Marley

Product Line

AquaTower

Model

AQ492G1BAF

Equipment Type

Induced-Draft Crossflow Cooling Tower

Condition

Used

Year Built

2019

Nominal Cooling Capacity

Approx. 28 Tons

Capacity Reference

Marley 492G Engineering Data

Rated Hot Water Temperature

95°F

Rated Cold Water Temperature

85°F

Rated Wet-Bulb Temperature

78°F

Rated Water Flow Basis

3 GPM per Nominal Ton

Calculated Nominal Circulation Flow

Approx. 84 GPM

Tower Configuration

Factory-Assembled Crossflow

Draft Type

Induced Draft

Fill Material

PVC Film Fill

Louvers

Integral

Drift Eliminators

Included

Fan Diameter

36"

Fan Motor

2 HP

Motor Speed

1,750 RPM

Electrical

208–230/460V

Phase

3 Phase

Frequency

60 Hz

Water Inlet

4"

Water Outlet

4"

Overall Length

72"

Overall Width

48"

Overall Height

90"

Serial Number

10183156-A1

The 28 nominal ton capacity is based on published engineering data for the 492G configuration and the stated rating conditions. Actual cooling performance depends on water flow, entering water temperature, ambient wet-bulb temperature, equipment condition, and system design. Capacity at other operating conditions should be confirmed.
Typical Applications

Commercial HVAC cooling systems

Industrial process cooling

Chiller condenser-water cooling

Heat exchanger cooling

Compressor cooling-water systems

Manufacturing equipment cooling

Recirculating cooling-water systems

Process temperature control

Industrial machinery heat rejection

Commercial building cooling

Cooling-water loop applications

Small industrial utility cooling systems

Equipment and Processes This Cooling Tower Could Be Used For

Water-cooled chillers

Industrial heat exchangers

Air compressors with water-cooling circuits

Plastic injection molding equipment

Plastic extrusion equipment

Industrial hydraulic systems

Process cooling skids

Water-cooled condensers

Manufacturing process equipment

Industrial water-cooling loops

Commercial HVAC condenser-water systems

Compatible liquid cooling systems

Actual suitability depends on required heat rejection capacity, circulating water flow, water chemistry, operating temperatures, and system integration requirements.
FAQ

WHAT IS THE NOMINAL COOLING CAPACITY OF THIS MARLEY AQUATOWER?
Marley engineering data for the 492G configuration lists approximately 28 nominal tons under the stated 95°F hot water, 85°F cold water and 78°F wet-bulb design conditions.

IS 28 TONS THE CAPACITY UNDER ALL OPERATING CONDITIONS?
No. Cooling-tower capacity varies with entering and leaving water temperature, wet-bulb temperature, water flow and site conditions.

WHAT TYPE OF COOLING TOWER IS THIS?
It is a factory-assembled induced-draft crossflow cooling tower.

WHAT TYPE OF FILL DOES IT USE?
The tower is equipped with PVC film fill.

DOES IT HAVE DRIFT ELIMINATORS?
Yes. Integral drift eliminators are part of the tower configuration.

WHAT SIZE FAN MOTOR DOES IT HAVE?
The tower is equipped with an approximately 2 HP fan motor.

WHAT SIZE ARE THE WATER CONNECTIONS?
The listed inlet and outlet connections are 4".

WHAT ARE THE APPROXIMATE DIMENSIONS?
Manufacturer-listed dimensions for the 492G configuration are approximately 3'-11-1/2" long x 5'-0-3/4" wide x 7'-4-1/2" high.

WHEN WAS THIS COOLING TOWER BUILT?
The unit was built in 2019.

CAN THIS COOLING TOWER BE USED WITH A CHILLER?
Yes. Possible applications include compatible condenser-water and heat-rejection systems serving water-cooled chillers, provided the tower capacity matches the required heat load and design conditions.

CAN IT BE USED FOR PROCESS COOLING?
Yes. It may be suitable for compatible industrial process cooling, heat exchangers, compressors and other recirculating-water systems.

CAN AARON EQUIPMENT HELP DETERMINE IF THIS TOWER IS LARGE ENOUGH FOR MY APPLICATION?
Yes. Aaron Equipment can help review your required tonnage, water flow, entering and leaving water temperatures and design wet-bulb temperature to determine whether this Marley AquaTower may be suitable.

CAN AARON EQUIPMENT ARRANGE SHIPPING?
Yes. Aaron Equipment can assist with freight, loading and shipping coordination for domestic or international destinations. Contact Aaron Equipment with your delivery location for shipping assistance.

Specs

Commercial HVAC cooling systems
Industrial process cooling
Chiller condenser-water cooling
Heat exchanger cooling
Compressor cooling-water systems
Manufacturing equipment cooling
Recirculating cooling-water systems
Process temperature control
Industrial machinery heat rejection
Commercial building cooling
Cooling-water loop applications
Small industrial utility cooling systems