USED AGILENT DADG1315B, COLG1316A, DEGASG1379A, BINPUMP G1312A, ALS G1329A
Overview
Agilent 1100 Series HPLC
This Agilent 1100 is a complete HPLC system with Binary pump, Diode Array Detector, Degasser with solvent tray, Column Compartment, including PC (not pictured) & licensed ChemStation software.
Note: other HPLC module combinations available (Capillary Pump, Multiple Wavelength Detector, Thermostated Column Compartment, see other listings for individual modules)
ALS Autosampler G1329A specifications -
Type
Specs
GLP features
Early maintenance feedback (EMF), electronic records of maintenance and errors
Communications
Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output
Safety features
Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display
Injection range
0.1 – 100 µl in 0.1 µl increments Up to 1500 µl with multiple draw (hardware modification
required)
Replicate injections
1 – 99 from one vial
Precision
Typically < 0.5 % RSD of peak areas from 5 – 100 µl, Typically < 1 % RSD of peak areas from 1 – 5 µl
Minimum sample volume
1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
Carryover
Typically < 0.1 %, < 0.05 % with external needle cleaning
Sample viscosity range
0.2 – 50 cp
Replicate injections per vial
1 – 99
Sample capacity
100 × 2-ml vials in 1 tray
40 × 2-ml vials in ½ tray
15 × 6-ml vials in ½ tray (Agilent vials only)
Injection cycle time
Typically 50 s depending on draw speed and injection volume
Diode Array Detector G1315B Features:
Features:
Access the spectral domain with superior 3D optics-simultaneous illumination using combined deuterium and tungsten lamps for highest intensity and lowest detection limit from 190 to 950 nm, 1024 diodes and 1-nm slit for highest spectral resolution.
Programmable slit helps you explore the spectral landscape for faster sample characterization-focus on fine bands with narrow setting, or if higher sensitivity is required open up the programmable slit for more light throughput. A broad slit ensures lowest baseline noise and highest chromatographic signal-to-noise. Store and report slit settings, from 1 - 16 nm, together with your raw data for GLP traceability.
Spectral storage and flexible viewing -easily overlaid spectra within a run or between runs.
Verify wavelength accuracy for GLP compliance-automatic holmium oxide filter (which can be set at the beginning of your chromatography) verifies that your wavelength is indeed what the setpoint says it is.
Degasser G1379A Specifications -
Type
Specification
Maximum flow rate
10 ml/min per channel
5-10 ml/min per at reduced degassing performance
Number of channels
4
Internal volume per channel
Typically 12 ml per channel
Materials in contact with solvent
PTFE, PEEK
Explore More Used Equipment Listings on Equipt
Browse related Used HPLC Systems, High-Performance Liquid Chromatography (HPLC, Chromatography, and Medical & Laboratory equipment, including AGILENT machines for sale on Equipt.
Used Equipment for Sale in California, United States
Find Used HPLC Systems, High-Performance Liquid Chromatography (HPLC, Chromatography, and AGILENT equipment for sale in California, United States, with related local Medical & Laboratory searches.
Used Equipment for Sale in United States
Browse Used HPLC Systems, High-Performance Liquid Chromatography (HPLC, Chromatography, and AGILENT equipment for sale across United States, including related Medical & Laboratory inventory paths.
Sell Your Used Equipment
Find dedicated pages to sell used HPLC Systems, High-Performance Liquid Chromatography (HPLC, Chromatography, Medical & Laboratory, and AGILENT equipment on Equipt.