USED AGILENT TECHNOLOGIES G4513A
Overview
Includes:
Agilent 7693 Autosampler (G4513A)
16 Position Turret
Warranty Coverage
Options:
Extended Warranty
Financing Available
Specs
15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
A refurbished Agilent 7697A Headspace, a headspace sampler. It samples the vapor above the sample for volatile analysis; it runs unattended sequences.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent built the 7697A on the same architecture as its 7890 GC and 7693A automatic liquid sampler. An inert sample pathway carries the vapor to the GC without analyte loss or degradation. An automatic leak check confirms each vial is sealed before the run starts. The sampler stores up to 32 user-defined headspace methods, plus five presets, and up to 9 sequences. An operator can run it standalone from a chemical-resistant keypad or over LAN through OpenLab CDS ChemStation, OpenLab CDS EZChrom, or MSD ChemStation. Independent control of vial pressurization and column head pressure keeps sample transfer free of backpressure. Priority sample positions accommodate a late-arriving sample without breaking the sequence. Barometric pressure compensation holds results consistent across instruments and labs. The 7697A runs on hydrogen as a carrier gas. Sleep and Wake modes cut gas and power use between runs.
What each component does
Vapor sampling
Samples the vapor above the sample for volatile analysis, without carrying the liquid or solid matrix into the GC.
Automated sequencing
Runs overnight sequences without an operator, working through the loaded tray on its own schedule.
Technical detail
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 7693 Tower is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Hydrocarbons and fuels
Solvents and fatty acids
Permanent and fixed gases
Pesticides and halogenated compounds
Nitrogen and phosphorus pesticides
Sulfur and phosphorus compounds
Volatiles and semivolatiles
Residual solvents confirmation
Pesticides and terpenes
Additional Information
Documentation
Financing
Put the financing content and link here.
Need a single detector instead?
Chimney won’t light or expanding an existing system? Every part in this system is available individually, in stock and performance-verified.
[In this system]
Agilent 7697A Headspace G4557A: Verified
Oven range 4 to 450°C: Verified
7683B Autosampler G2614A: Verified
Optional Inlets Optional Detectors: Verified
Workstation loaded with software: Included
[Each component is individually serialized and performance-verified before the system is assembled and tested as a complete system.]
Injection type: Single or dual simultaneous
Sample prep: Sandwich injection, three layers
Compatibility: Agilent 7693A ALS system only
Optional module: Heater and mixer for sample prep
Condition: Certified Refurbished
Software: Loaded on workstation
Condition: Refurbished
Model: G4513A
OEM: Agilent Technologies
Financing: Financing Options Available
Explore More Used Equipment Listings on Equipt
Browse related Used Lab Autosamplers, Spectrometers, Analytical Instruments, and Medical & Laboratory equipment, including AGILENT machines for sale on Equipt.
Used Equipment for Sale in New York, United States
Find Used Lab Autosamplers, Spectrometers, Analytical Instruments, and AGILENT equipment for sale in New York, United States, with related local Medical & Laboratory searches.
Used Equipment for Sale in United States
Browse Used Lab Autosamplers, Spectrometers, Analytical Instruments, and AGILENT equipment for sale across United States, including related Medical & Laboratory inventory paths.
Sell Your Used Equipment
Find dedicated pages to sell used Lab Autosamplers, Spectrometers, Analytical Instruments, Medical & Laboratory, and AGILENT equipment on Equipt.