USED AGILENT TECHNOLOGIES 7694
Overview
Includes:
HP 7694 Headspace Autosampler
Automated 44-sample tray
115V Configuration
General Purpose Remote Cable
Integrates seamlessly with Agilent 5890 GC
Warranty Coverage
Options:
Extended Warranty
Cables to connect to specific instruments must be purchased separately
Financing Available
Specs
15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
A refurbished HP/Agilent 7694 headspace autosampler. It samples the vapor above the sample for volatile analysis and runs unattended sequences from a 44-vial tray.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
The 7694 automates static headspace sampling for up to 44 samples without operator attention, loading six vials at a time from the tray into a circular aluminum carousel. Three heated zones, the vial oven, the sample loop, and the transfer line, condition the sample before injection, with a setpoint range of 40 to 200 degrees Celsius. GC cycle time runs from 1 to 999 minutes. The sampler stores up to four methods and increments run parameters automatically to speed method development. It draws up to 10 headspace extractions from a single vial and offers two levels of vial agitation to speed equilibration. An inert flow path from the vial to the GC column head limits sample absorption. Agilent designed the 7694 for HP 5890 series and Agilent 6890 series GCs. The manual warns against using hydrogen as a carrier gas in the 7694.
What each component does
Vapor sampling
Samples the vapor above the sample for volatile analysis, heating each vial in the oven before extraction and transfer to the GC.
Automated sequencing
Runs overnight sequences from the 44-vial tray without an operator, cycling six vials at a time through the carousel.
Technical detail
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 7694 is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Hydrocarbons and fuels
Solvents and fatty acids
Permanent and fixed gases
Pesticides and halogenated compounds
Nitrogen and phosphorus pesticides
Sulfur and phosphorus compounds
Volatiles and semivolatiles
Residual solvents confirmation
Pesticides and terpenes
Additional Information
Documentation
Financing
Put the financing content and link here.
Need a single detector instead?
Chimney won’t light or expanding an existing system? Every part in this system is available individually, in stock and performance-verified.
[In this system]
HP/Agilent 7694 Headspace Autosampler G1290A: Verified
Oven range 4 to 450°C: Verified
7683B Autosampler G2614A: Verified
Optional Inlets Optional Detectors: Verified
Workstation loaded with software: Included
[Each component is individually serialized and performance-verified before the system is assembled and tested as a complete system.]
Vial capacity: 44-vial tray, 6 in carousel at a time
Setpoint temperature: 40 to 200°C
Heated zones: Vial oven, sample loop, transfer line
GC cycle time: 1 to 999 min
Extraction modes: Up to 10 extractions per vial, 2 agitation levels
Condition: Certified Refurbished
Software: Loaded on workstation
Model: 7694
OEM: Agilent Technologies
Financing: Financing Options Available
Explore More Used Equipment Listings on Equipt
Browse related Used Lab Autosamplers, Spectrometers, Analytical Instruments, and Medical & Laboratory equipment, including AGILENT machines for sale on Equipt.
Used Equipment for Sale in New York, United States
Find Used Lab Autosamplers, Spectrometers, Analytical Instruments, and AGILENT equipment for sale in New York, United States, with related local Medical & Laboratory searches.
Used Equipment for Sale in United States
Browse Used Lab Autosamplers, Spectrometers, Analytical Instruments, and AGILENT equipment for sale across United States, including related Medical & Laboratory inventory paths.
Sell Your Used Equipment
Find dedicated pages to sell used Lab Autosamplers, Spectrometers, Analytical Instruments, Medical & Laboratory, and AGILENT equipment on Equipt.