Your Cart
You don't have any items in your cart.
Used

USED AGILENT TECHNOLOGIES G4514A

New York, United States
558Listings|1Follower
Overview
Lab Autosamplers

Includes:
Agilent 7693 Tray

150 Sample

Warranty Coverage
Financing Available

Specs

15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
A refurbished Agilent 7693 Tray (G4514), an autosampler tray. It holds and positions vials for the autosampler tower; it runs unattended sequences.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent scales the 7693A around the same modular tray system: 16 vials as a start, up to 150 vials for long unattended runs. The tray holds and positions each vial for the injector tower on its turn in the sequence. Agilent offers whole-tray heating, or cooling to sub-ambient temperatures, to condition samples before injection. A priority sample position lets an operator insert an urgent sample without stopping the running sequence.
What each component does
Vapor sampling
Holds and positions vials for the autosampler tower, presenting each one in turn so the injector always draws from the correct position.
Automated sequencing
Runs overnight sequences without an operator, working through the loaded tray on its own schedule.
Technical detail
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 7693 Tray is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Hydrocarbons and fuels
Solvents and fatty acids
Permanent and fixed gases
Pesticides and halogenated compounds
Nitrogen and phosphorus pesticides
Sulfur and phosphorus compounds
Volatiles and semivolatiles
Residual solvents confirmation
Pesticides and terpenes
Additional Information
Documentation
Financing

Put the financing content and link here.
Need a single detector instead?
Chimney won’t light or expanding an existing system? Every part in this system is available individually, in stock and performance-verified.
[In this system]
Agilent 7697A Headspace G4557A: Verified
Oven range 4 to 450°C: Verified
7683B Autosampler G2614A: Verified
Optional Inlets Optional Detectors: Verified
Workstation loaded with software: Included
[Each component is individually serialized and performance-verified before the system is assembled and tested as a complete system.]
Vial capacity: 16 to 150 vials
Sample conditioning: Whole-tray heating or sub-ambient cooling
Priority samples: Insert without stopping the sequence
Compatibility: Agilent 7693A ALS system only
Condition: Certified Refurbished
Software: Loaded on workstation
Condition: Refurbished
Model: G4514A
OEM: Agilent Technologies
Financing: Financing Options Available

Loading...
Loading...