USED AGILENT TECHNOLOGIES G1330B
Overview
Includes:
Agilent 1200 HPLC ALS Thermostat (G1330B)
In-House Warranty Coverage
Options:
Installation & Familiarization
Extended Warranty
Financing Available
Specs
15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
A refurbished Agilent 1200 Series G1330B ALS thermostat. It holds samples at a set temperature in the autosampler tray, protecting temperature-sensitive samples before injection.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this module
Agilent built the G1330B around the same Peltier-controlled heat exchangers as the G1330A, with a settable temperature range of 4 to 40 degrees Celsius in 1-degree increments. Temperature accuracy holds to between -1 and +4 degrees Celsius at a 4-degree setpoint when ambient temperature stays under 25 degrees Celsius and humidity under 50 percent, widening to +5 degrees Celsius above that ambient threshold. The thermostat pairs with the G1389A, G1367A, or G2260A autosampler module over a control cable, with each module keeping its own power supply. It works with other 1200 or 1290 Infinity Series modules, or with other LC systems that have adequate remote control inputs and outputs, controlled from the Agilent Instant Pilot or from Agilent’s own LC control software. The thermostatted sample tray holds 100 1.8-milliliter vials, or two well plates plus 10 1.8-milliliter vials. The unit operates up to 2000 meters altitude and tolerates humidity under 95 percent at 40 degrees Celsius without condensing. It measures 13.5 by 17 by 5.5 inches and weighs 20.7 kilograms.
What this module does
Sample thermostatting
Holds samples in the autosampler tray at a set temperature, using Peltier-controlled heating and cooling, protecting temperature-sensitive samples before injection.
Autosampler pairing
Connects to a G1389A, G1367A, or G2260A autosampler module over a control cable, each keeping its own power supply.
Technical detail
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same specific stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 1200 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Assay, Impurity and dissolution
The 1200 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.
EPA HPLC methods
Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.
Additives and vitamins
The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.
Cannabinoid potency
HPLC with UV detection is the reference technique for potency. The 1200 resolves the major cannabinoids for compliance and label-claim testing.
Botanical actives
Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.
Screening and drug monitoring
The 1200 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.
Purity and additives
Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.
Four-solvent scouting
Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.
Proteomics, metabolomics, lipidomics
Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1200 serves as the front end feeding your MS or fraction collector.
Additional Information
Documentation
Financing
Agilent 1200 series Autosampler Thermostat (G1330B) User Manual
Finance Your Laboratory Instruments with Confidence. Options that fit your budget.
GenTech Scientific, powered by Trio Capital, offers tailored financing options for your next equipment lease or instrument purchase. We make financing simple so you can obtain the equipment you need, maximize your lab’s budget, and focus on the science.
Finance today!
Need another single module?
Replacing a failed pump? Expanding an existing stack? Shop our inventory of performance-verified instruments and upgrades.
[In this listing]
Agilent 1200 ALS Thermostat G1330B: Verified
[Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system.]
Temperature range: 4 to 40°C, 1°C increments
Temperature accuracy: -1 to +4°C (below 25°C ambient)
Sample capacity support: 100 x 1.8-mL vials, or 2 wellplates + 10 vials
Weight / dimensions: 20.7 kg, 34.5 x 43.5 x 14 cm
Compatible autosamplers: G1389A, G1367A, G2260A
Key Features: Peltier Control, Air Circulation, Condensation Management, System Integration via CAN interface
Weight: 45 lbs
Dimensions: 24 × 24 × 24 in
Model: G1330B
OEM: Agilent Technologies
Financing: Financing Options Available
Explore More Used Equipment Listings on Equipt
Browse related Used HPLC Autosamplers, High-Performance Liquid Chromatography (HPLC, Chromatography, and Medical & Laboratory equipment, including AGILENT machines for sale on Equipt.
Used Equipment for Sale in New York, United States
Find Used HPLC Autosamplers, High-Performance Liquid Chromatography (HPLC, Chromatography, and AGILENT equipment for sale in New York, United States, with related local Medical & Laboratory searches.
Used Equipment for Sale in United States
Browse Used HPLC Autosamplers, High-Performance Liquid Chromatography (HPLC, Chromatography, and AGILENT equipment for sale across United States, including related Medical & Laboratory inventory paths.
Sell Your Used Equipment
Find dedicated pages to sell used HPLC Autosamplers, High-Performance Liquid Chromatography (HPLC, Chromatography, Medical & Laboratory, and AGILENT equipment on Equipt.

