Your Cart
You don't have any items in your cart.
Used

USED AGILENT TECHNOLOGIES G1312A

New York, United States
558Listings|1Follower
Overview
HPLC Systems

Includes:
Agilent 1200 Binary Pump (G1312A)

CAN Cable

In-House Warranty Coverage
Options:
Installation & Familiarization
Extended Warranty
Financing Available

Specs

15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
A refurbished Agilent 1200 Series G1312A binary pump. It delivers a two-solvent high-pressure gradient at constant, low-pulse flow.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent built the G1312A around a two-channel, dual-piston in-series design, with two pump assemblies each capable of pressure to 400 bar. Electronically controlled active inlet valves need little maintenance at flow rates to 5 milliliters per minute. Floating pistons and a path-of-least-resistance seal design extend seal life. Pressure pulsation stays under 2 percent amplitude, typically under 1 percent, at 1 milliliter per minute of isopropanol above 1 megapascal. Gradient delay volume runs 180 to 480 microliters without a mixer, or 600 to 900 microliters with one, depending on back pressure. Composition holds to a range of 1 to 99 percent, or 5 microliters per minute per channel, whichever is greater. A handheld control module enters operating parameters, stores methods, and displays the pressure profile and diagnostics. Early Maintenance Feedback tracks seal wear and pumped volume against user-set limits. The pump communicates over CAN, GPIB, RS-232C, and APG Remote, with LAN available as an option.
 
What each module does
Pump
Delivers the mobile phase at constant flow and blends the gradient. Isocratic, binary, and quaternary configurations cover everything from single-solvent assays to four-solvent method scouting. Stable flow is the basis for the retention-time reproducibility every quantitative method depends on.
Binary pumping
Delivers a two-solvent high-pressure gradient at constant, low-pulse flow. Stable, low-pulse flow is the basis for the retention-time reproducibility every quantitative method depends on. Rated to 400 bar.
Technical detail
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 1200 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Assay, Impurity and dissolution
The 1200 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.
EPA HPLC methods
Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.
Additives and vitamins
The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.
Cannabinoid potency
HPLC with UV detection is the reference technique for potency. The 1200 resolves the major cannabinoids for compliance and label-claim testing.
Botanical actives
Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.
Screening and drug monitoring
The 1200 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.
Purity and additives
Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.
Four-solvent scouting
Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.
Proteomics, metabolomics, lipidomics
Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1200 serves as the front end feeding your MS or fraction collector.
Additional Information
Documentation
Financing

Agilent 1200 Series Binary Pump Manual
Financing Options Available.  Finance Builder.
Need a single module instead?
Replacing a failed pump or expanind an existing stack? Every module in this system is available individually, in stock and performance-verified.
[In this stack]
Agilent 1200 Binary Pump G1312A: Verified
1260 Vialsampler G7129A: Verified
1260 Multicolumn Thermostat G7116A: Verified
1260 Diode Array Detector G7115A: Verified
Workstation loaded with software: Included
[Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system.]
Max pressure: 400 bar to 5 mL/min
Pressure pulsation: 2% amplitude, typically 1%
Delay volume: 180 to 480 µL (600 to 900 µL with mixer)
Composition range: 1 to 99%, or 5 µL/min per channel
Communication: CAN, GPIB, RS-232C, APG Remote, optional LAN
Software: Loaded on workstation
Model: G1312A
OEM: Agilent Technologies
Condition: Refurbished
Financing: Financing Options Available

Loading...
Loading...
Loading...