USED AGILENT TECHNOLOGIES G1321A

New York, United States
558Listings|1Follower
Overview
HPLC Detectors

Includes:
Agilent 1200 Fluorescence Detector (FLD)
In-House Warranty Coverage
Options:
Installation & Familiarization
Extended Warranty
Financing Available

Specs

15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
A refurbished Agilent 1200 Series G1321A fluorescence detector. It measures fluorescence emission for sensitive, selective detection of fluorophores.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent built the G1321A as a multi-signal fluorescence detector with on-line scanning and spectral data analysis. A xenon flash lamp runs at 20 watts in normal mode or 5 watts in economy mode, pulsing at 296 Hz for single-signal work and 74 Hz in spectral mode. The excitation monochromator covers 200 to 700 nanometers plus zero order, with a fixed 20-nanometer bandwidth through a concave holographic grating. Agilent rates sensitivity at 10 femtograms of anthracene at 250/400 nanometer excitation and emission. The standard quartz flow cell holds 8 microliters and takes up to 20 bar; an optional cuvette accessory runs the same 8-microliter volume for offline spectroscopic measurements. A built-in PMT gain test checks detector response as part of routine diagnostics. ChemStation for LC or the 1100 Control Module runs the detector, with CAN, GPIB, and RS-232C for communication.
 
What each module does
Fluorescence detection
Measures fluorescence emission for sensitive, selective detection of fluorophores, with programmable excitation and emission wavelengths. It drops into a compatible 1200 HPLC stack under OpenLab CDS or ChemStation.
Technical detail
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 1200 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Assay, Impurity and dissolution
The 1200 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.
EPA HPLC methods
Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.
Additives and vitamins
The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.
Cannabinoid potency
HPLC with UV detection is the reference technique for potency. The 1200 resolves the major cannabinoids for compliance and label-claim testing.
Botanical actives
Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.
Screening and drug monitoring
The 1200 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.
Purity and additives
Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.
Four-solvent scouting
Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.
Proteomics, metabolomics, lipidomics
Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1200 serves as the front end feeding your MS or fraction collector.
Additional Information
Documentation
Financing

Financing Options Available.  Finance Builder.
Need a single module instead?
Replacing a failed pump or expanind an existing stack? Every module in this system is available individually, in stock and performance-verified.
[In this stack]
Agilent 1200 HPLC G7111B: Verified
Agilent 1200 FLD G1321A: Verified
1260 Multicolumn Thermostat G7116A: Verified
1260 Diode Array Detector G7115A: Verified
Workstation loaded with software: Included
[Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system.]
Detection type: Multi-signal, simultaneous wavelengths
Light source: Xenon flash lamp, 20 W / 5 W economy
Excitation range: 200 to 700 nm, plus zero order
Sensitivity: 10 fg anthracene (Ex 250/Em 400 nm)
Flow cell: 8 µL quartz, 20 bar max
Software: Loaded on workstation
Condition: Refurbished
Model: G1321A
OEM: Agilent Technologies
Financing: Financing Options Available