USED AGILENT TECHNOLOGIES G1367E
Overview
Includes:
Agilent 1260 Infinity High Performance Autosampler (G1367E)
CAN Cable
In-House Warranty Coverage
Options:
Extended Warranty
Installation & Familiarization
Financing Available
Specs
15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
A refurbished Agilent 1260 Infinity G1329B autosampler. It draws a precise volume and injects it onto the column, with a standard analytical head and optional preparative heads for higher-volume injections.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent built the G1329B around a standard analytical head with an injection range of 0.1 to 100 microliters. Optional preparative heads extend injection volume to 900 microliters, one rated to 200 bar and the other to 400 bar; an SL configuration keeps the 100-microliter analytical head but raises the pressure limit to 600 bar. An X-Z-Theta transport mechanism positions the gripper arm for vial pickup, monitored by optical sensors and encoders to confirm correct operation. The metering device flushes after every injection to hold carryover down. The standard 1260 configuration includes a 100-vial thermostatted tray, a 40-vial tray, a 15-vial tray, and an electrically actuated 600-bar Rheodyne injection valve. The autosampler pairs with the 1290 Infinity Thermostat, the G1330B, for temperature-sensitive samples. It integrates with 1200 Infinity Series, 1200 Series, and 1100 Series LC systems, controlled through Agilent OpenLab software or another chromatography data system.
What each module does
Liquid injection
Draws a precise volume from the vial or well and injects it onto the column, using an X-Z-Theta transport mechanism to position the gripper arm for each pickup.
Automated sequencing
Runs unattended sequences from a 100-vial tray, with 40-vial and 15-vial trays also available.
Technical detail
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 1260 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Assay, Impurity and dissolution
The 1260 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.
EPA HPLC methods
Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.
Additives and vitamins
The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.
Cannabinoid potency
HPLC with UV detection is the reference technique for potency. The 1260 resolves the major cannabinoids for compliance and label-claim testing.
Botanical actives
Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.
Screening and drug monitoring
The 1260 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.
Purity and additives
Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.
Four-solvent scouting
Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.
Proteomics, metabolomics, lipidomics
Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1200 serves as the front end feeding your MS or fraction collector.
Additional Information
Documentation
Financing
Agilent 1260 Infinity HiP AS (G1367E) User Manual
Financing Options Available. Finance Builder.
Need a single module instead?
Replacing a failed pump or expanind an existing stack? Every module in this system is available individually, in stock and performance-verified.
[In this stack]
Agilent 1260 Autosampler G1329B: Verified
1260 Vialsampler G7129A: Verified
1260 Multicolumn Thermostat G7116A: Verified
1260 Diode Array Detector G7115A: Verified
Workstation loaded with software: Included
[Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system.]
Injection range (standard): 0.1 to 100 µL
Injection range (prep heads): 0.1 to 900 µL, 200 or 400 bar
SL configuration: 100 µL head, up to 600 bar
Injection valve: Electrically actuated, 600-bar Rheodyne
Tray options: 100-vial, 40-vial, or 15-vial trays
Software: Loaded on workstation
Condition: Refurbished
Model: G1367E
OEM: Agilent Technologies
Financing: Financing Options Available
Explore More Used Equipment Listings on Equipt
Browse related Used HPLC Autosamplers, High-Performance Liquid Chromatography (HPLC, Chromatography, and Medical & Laboratory equipment, including AGILENT machines for sale on Equipt.
Used Equipment for Sale in New York, United States
Find Used HPLC Autosamplers, High-Performance Liquid Chromatography (HPLC, Chromatography, and AGILENT equipment for sale in New York, United States, with related local Medical & Laboratory searches.
Used Equipment for Sale in United States
Browse Used HPLC Autosamplers, High-Performance Liquid Chromatography (HPLC, Chromatography, and AGILENT equipment for sale across United States, including related Medical & Laboratory inventory paths.
Sell Your Used Equipment
Find dedicated pages to sell used HPLC Autosamplers, High-Performance Liquid Chromatography (HPLC, Chromatography, Medical & Laboratory, and AGILENT equipment on Equipt.