HPLC Systems

Designed for maximum flexibility and robustness, the Agilent 1200 LC System features a modular architecture that easily adapts to your lab’s evolving needs. Configure the system to match your precise HPLC and UHPLC requirements, giving you complete control over your analytical capabilities without unnecessary complexity.
Includes:
Agilent 1200 HPLC System

Agilent 1200 Vacuum Degasser
Agilent 1200 Pump (Binary or Quaternary)
Agilent 1200 Detector (VWD or DAD)

PAL Autosampler

100 ul Syringe holder
6 port LC Injection Valve
Control Terminal
Deepwell 3 Drawer Plate Stack

Data System
In-House Warranty Coverage
Options:
Workbench
Column Compartment
Module Customization
Installation & Familiarization
Extended Warranty
Financing Available

Specs

15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
An Agilent 1200 HPLC pump and detector, paired with a CTC Analytics PAL autosampler. The pump drives the mobile phase through the column at constant, reproducible flow. The PAL autosampler injects a precise sample volume onto the column. The detector measures each compound as it elutes.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
This system pairs a CTC Analytics PAL autosampler with an Agilent 1200 HPLC pump and detector. The PAL handles injection volumes from 10 to 100 microliters, with a Peltier-based thermostat option for temperature-sensitive samples. It runs on 100 to 240 volts at 150 VA and accepts a range of sample formats, including standard 2-milliliter vials and microplates. The Agilent 1200 pump delivers the mobile phase at constant, reproducible flow, in isocratic, binary, or quaternary configurations. The Agilent 1200 detector, typically a variable wavelength or diode array unit, measures each compound as it elutes.
 
What each module does
Pump
Delivers the mobile phase at constant flow and blends the gradient. Isocratic, binary, and quaternary configurations cover single-solvent assays through four-solvent method scouting.
PAL autosampler
Draws a precise volume from a vial or microplate and injects it onto the column, with an injection range of 10 to 100 microliters and an optional Peltier thermostat for temperature-sensitive samples.
Detector
Measures each compound as it leaves the column. A variable-wavelength or diode array detector covers most routine HPLC methods.
Technical detail
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The 1200 HPLC is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Assay, Impurity and dissolution
The 1200 transfers cleanly into USP monograph assays, related-substance profiling, and dissolution testing. Quaternary blending simplifies mobile-phase transfer between labs.
EPA HPLC methods
Diode array detection supports EPA HPLC methods for contaminants and residues in water and soil, including PAHs, explosives, and carbamates.
Additives and vitamins
The system quantifies preservatives, sweeteners, organic acids, and fat-soluble vitamins at the throughput a production-support lab needs.
Cannabinoid potency
HPLC with UV detection is the reference technique for potency. The 1200 resolves the major cannabinoids for compliance and label-claim testing.
Botanical actives
Labs quantify polyphenols, flavonoids, and marker compounds in extracts and nutraceutical formulations across long, reproducible sequences.
Screening and drug monitoring
The 1200 runs HPLC-UV workflows for therapeutic drug monitoring and drugs-of-abuse screening, where method portability and uptime matter more than peak novelty.
Purity and additives
Industrial labs separate and quantify synthesis intermediates, polymer additives, and stabilizers for QC and release testing.
Four-solvent scouting
Agilent recommends the quaternary pump for method development. Blend up to four solvents to scout selectivity before you lock a final method.
Proteomics, metabolomics, lipidomics
Many omics workflows use mass spectrometry for detection and rely on LC for separation. The 1200 serves as the front end feeding your MS or fraction collector.
Additional Information
Documentation
Financing

Financing Options Available.  Finance Builder.
Need a single module instead?
Replacing a failed pump or expanind an existing stack? Every module in this system is available individually, in stock and performance-verified.
[In this stack]
Agilent 1200 Front End PAL Autosampler: Verified
1260 Vialsampler G7129A: Verified
1260 Multicolumn Thermostat G7116A: Verified
1260 Diode Array Detector G7115A: Verified
Workstation loaded with software: Included
[Each module is individually serialized and performance-verified before the stack is assembled and tested as a complete system.]
Pump options: Isocratic, binary, quaternary
Detector options: Variable wavelength or diode array
PAL Autosampler
Injection range: 10 to 100 µL
Thermostat option: Peltier-based
Software: Loaded on workstation
Condition: Refurbished
Model: 1200, PAL
OEM: Agilent Technologies, CTC Analytics
Financing: Financing Options Available