USED AGILENT TECHNOLOGIES 9000
Overview
Includes:
Agilent Intuvo 9000 GC System
Split/Splitless Inlet
Dual Flame Ionization Detectors (FID)
Agilent 7697A Headspace
Data System
Warranty Coverage
Options:
GC Starter Kit
Workbench – Browse
Installation & Familiarization
Extended Warranty
Financing Available
Specs
15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
High-throughput petrochemical, food-safety, and environmental methods run on the fast, low-maintenance separations the Intuvo 9000 delivers. A Guard Chip protects the flow path from contamination and eliminates the ferrule connections and column clipping older GC platforms require. The direct-heated oven ramps from 30 to 450°C at up to 250°C per minute. Ballistic column heating cuts cycle time between runs. GenTech rebuilds, plumbs, and tests the flow path chips, detectors, and oven, then verifies the instrument against reference standards. You receive an Intuvo that arrives verified and ready to run your methods.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent positions the Intuvo 9000 as a step beyond conventional GC architecture. A Guard Chip, a single-use consumable, seals the flow path and protects downstream components from contamination; Agilent’s no-trim columns click into place without ferrules or a wrench. Smart Keys attached to the flow path components identify configuration and column age and load default method parameters automatically. Built-in intelligence tracks more than 100 instrument parameters in real time and walks an operator through self-guided troubleshooting and maintenance. Agilent cites 30 to 450°C oven ramps at up to 250°C per minute from direct, ballistic column heating, faster and more reproducible than a conventional convection oven. Agilent pairs the Intuvo 9000 with its 5977, 7000, and 7010 mass spectrometers for GC-MS configurations.
What each component does
Guard Chip and flow path
A single-use Guard Chip seals the flow path and protects downstream components from contamination. Ferrule-free, click-and-run connections let an operator swap a column in under a minute without tools or leak checks.
Column oven
Direct, ballistic heating replaces a conventional convection oven and ramps from 30 to 450°C at up to 250°C per minute. Faster, more repeatable ramps shorten cycle time between injections.
Inlet and detector chips
Inlets and detectors install as planar chip modules instead of separately plumbed hardware. A chip change replaces the manual reconfiguration a conventional GC needs to switch detection chemistry.
Smart Keys
Smart Keys attached to flow path components identify the installed configuration and column age and load the default method parameters for that setup, which cuts setup error at changeover.
Built-in intelligence
Onboard diagnostics track more than 100 instrument parameters in real time and walk an operator through self-guided maintenance and troubleshooting instead of a service call.
Technical detail
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The Intuvo 9000 is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Hydrocarbons and fuels
Solvents and fatty acids
Permanent and fixed gases
Pesticides and halogenated compounds
Nitrogen and phosphorus pesticides
Sulfur and phosphorus compounds
Volatiles and semivolatiles
Residual solvents confirmation
Pesticides and terpenes
Additional Information
Documentation
Financing
Installation and First Startup
Maintenance Manual
Operation Manual
Troubleshooting Manual
Agilent Intuvo 9000 GC Analyzer For Blood Alcohol Concentration
Agilent Intuvo 9000 GC Data Sheet
Agilent Intuvo 9000 GC Brochure
Tech Brief: Response & Retention Time | Equivalency to Agilent 7890B GC
Analysis of Blood Alcohol Concentration with an Agilent Intuvo 9000 GC System | Application Note
Novel Residual Solvents Analysis of Cannabinoid Products with the Agilent Headspace-GC/MS system
This cannabis testing application note is for the Agilent 7697A Headspace Sampler with the Agilent Intuvo 9000 system.
Financing Options Available. Finance Builder.
Need a single detector instead?
Chimney won’t light or expanding an existing system? Every part in this system is available individually, in stock and performance-verified.
15-Day
Refurbishment cadence
OEM-Spec
Verified against OEM and published benchmarks; report included.
On-Staff
Solution Scientists
Since 1996
Three decades supporting labs
What you are buying
High-throughput petrochemical, food-safety, and environmental methods run on the fast, low-maintenance separations the Intuvo 9000 delivers. A Guard Chip protects the flow path from contamination and eliminates the ferrule connections and column clipping older GC platforms require. The direct-heated oven ramps from 30 to 450°C at up to 250°C per minute. Ballistic column heating cuts cycle time between runs. GenTech rebuilds, plumbs, and tests the flow path chips, detectors, and oven, then verifies the instrument against reference standards. You receive an Intuvo that arrives verified and ready to run your methods.
Every unit moves through the GenTech Certified process. Solution Scientists disassemble and inspect each module, replace all consumables and degraded wear components, then tune and calibrate the instrument and verify performance against OEM and published benchmarks using known reference chemicals. The instrument ships with its verification report. A certified-refurbished system gives you that performance without the capital cost or the lead time of a new purchase.
What Agilent says about this platform
Agilent positions the Intuvo 9000 as a step beyond conventional GC architecture. A Guard Chip, a single-use consumable, seals the flow path and protects downstream components from contamination; Agilent’s no-trim columns click into place without ferrules or a wrench. Smart Keys attached to the flow path components identify configuration and column age and load default method parameters automatically. Built-in intelligence tracks more than 100 instrument parameters in real time and walks an operator through self-guided troubleshooting and maintenance. Agilent cites 30 to 450°C oven ramps at up to 250°C per minute from direct, ballistic column heating, faster and more reproducible than a conventional convection oven. Agilent pairs the Intuvo 9000 with its 5977, 7000, and 7010 mass spectrometers for GC-MS configurations.
What each component does
Guard Chip and flow path
A single-use Guard Chip seals the flow path and protects downstream components from contamination. Ferrule-free, click-and-run connections let an operator swap a column in under a minute without tools or leak checks.
Column oven
Direct, ballistic heating replaces a conventional convection oven and ramps from 30 to 450°C at up to 250°C per minute. Faster, more repeatable ramps shorten cycle time between injections.
Inlet and detector chips
Inlets and detectors install as planar chip modules instead of separately plumbed hardware. A chip change replaces the manual reconfiguration a conventional GC needs to switch detection chemistry.
Smart Keys
Smart Keys attached to flow path components identify the installed configuration and column age and load the default method parameters for that setup, which cuts setup error at changeover.
Built-in intelligence
Onboard diagnostics track more than 100 instrument parameters in real time and walk an operator through self-guided maintenance and troubleshooting instead of a service call.
Technical detail
*OEM specifications for brand new instrument.
What “GenTech Certified” means
Refurbishment at GenTech is a defined process, not a wipe-down. Every system moves through the same five stages.
1. Disassembly and rebuild. Solution Scientists strip the instrument down, clean each module inside and out, and rebuild it from the frame up. They replace pump seals, pistons, and check valves to specification.
2. Configuration and new parts. Solution Scientists install the options and modules you selected and fit new wear parts throughout. They replace the detector lamp with a new one and reset the lamp hours.
3. Diagnostic and performance testing. Solution Scientists tune and calibrate the instrument, run system diagnostics, and confirm detector wavelength accuracy. They test full-system pressure and gradient performance against OEM and published benchmarks using known reference chemicals.
4. Data package you approve before shipment. The verification data goes to you for approval before the system leaves the bench. You see exactly how the instrument performs before it ships.
5. Delivery and installation. The instrument ships in protective packing with a one-year warranty option and professional installation available from a GenTech Solution Scientist.
Labs that run this system
The Intuvo 9000 is method-compatible across the techniques most regulated and research labs run every day. These are the application areas buyers ask about most.
Hydrocarbons and fuels
Solvents and fatty acids
Permanent and fixed gases
Pesticides and halogenated compounds
Nitrogen and phosphorus pesticides
Sulfur and phosphorus compounds
Volatiles and semivolatiles
Residual solvents confirmation
Pesticides and terpenes
Additional Information
Documentation
Financing
Installation and First Startup
Maintenance Manual
Operation Manual
Troubleshooting Manual
Agilent Intuvo 9000 GC Analyzer For Blood Alcohol Concentration
Agilent Intuvo 9000 GC Data Sheet
Agilent Intuvo 9000 GC Brochure
Tech Brief: Response & Retention Time | Equivalency to Agilent 7890B GC
Analysis of Blood Alcohol Concentration with an Agilent Intuvo 9000 GC System | Application Note
Novel Residual Solvents Analysis of Cannabinoid Products with the Agilent Headspace-GC/MS system
This cannabis testing application note is for the Agilent 7697A Headspace Sampler with the Agilent Intuvo 9000 system.
Financing Options Available. Finance Builder.
Need a single detector instead?
Chimney won’t light or expanding an existing system? Every part in this system is available individually, in stock and performance-verified.
[In this system]
Agilent Intuvo 9000 GC G4581A: Verified
Detectors Dual FID: Verified
Inlet Split/Splitless (S/S): Verified
Agilent 7697A Headspace Sampler G4557A: Verified
Workstation with preloaded software: Included
[Each component is individually serialized and performance-verified before the system is assembled and tested as a complete system.]
Oven range: 30 to 450°C
Max ramp rate: 250°C/min, direct ballistic heating
Column change: Under 1 minute, no ferrules
Diagnostics: 100+ parameters monitored in real time
MS compatibility: Agilent 5977, 7000, 7010
Condition: Certified Refurbished
Software: Loaded on workstation
Model: 9000, 7697A
OEM: Agilent Technologies
Condition: Refurbished
Financing: Financing Options Available
[In this system]
Agilent Intuvo 9000 GC G4581A: Verified
Oven range 30 to 450°C: Verified
7683B Autosampler G2614A: Verified
Optional Inlets Optional Detectors: Verified
Workstation loaded with software: Included
[Each component is individually serialized and performance-verified before the system is assembled and tested as a complete system.]
Oven range: 30 to 450°C
Max ramp rate: 250°C/min, direct ballistic heating
Column change: Under 1 minute, no ferrules
Diagnostics: 100+ parameters monitored in real time
MS compatibility: Agilent 5977, 7000, 7010
Condition: Certified Refurbished
Software: Loaded on workstation
Model: 9000, 7697A
OEM: Agilent Technologies
Condition: Refurbished
Financing: Financing Options Available
Explore More Used Equipment Listings on Equipt
Browse related Used GC Systems, Gas Chromatography (GC), Chromatography, and Medical & Laboratory equipment, including AGILENT machines for sale on Equipt.
Used Equipment for Sale in New York, United States
Find Used GC Systems, Gas Chromatography (GC), Chromatography, and AGILENT equipment for sale in New York, United States, with related local Medical & Laboratory searches.
Used Equipment for Sale in United States
Browse Used GC Systems, Gas Chromatography (GC), Chromatography, and AGILENT equipment for sale across United States, including related Medical & Laboratory inventory paths.
Sell Your Used Equipment
Find dedicated pages to sell used GC Systems, Gas Chromatography (GC), Chromatography, Medical & Laboratory, and AGILENT equipment on Equipt.