Your Cart
You don't have any items in your cart.

USED WATERS XEVO G2-S QTOF

Overview
Manufacturer:
WATERS
Stock #:
02698
Description

The Waters Xevo™ G2-S QTof is a high-resolution Quadrupole Time-of-Flight (QToF) mass spectrometer designed for qualitative and quantitative LC-MS applications. The instrument combines a high-performance quadrupole mass filter with QuanTof™ TOF technology and StepWave™ ion optics to provide excellent sensitivity, accurate mass measurement, high mass resolution, and a wide dynamic range.

The Xevo G2-S supports MS, MS/MS, MSE® (data-independent acquisition), and FastDDA workflows, making it ideal for proteomics, metabolomics, biopharmaceutical characterization, impurity profiling, food safety, environmental analysis, and pharmaceutical research. It integrates seamlessly with ACQUITY UPLC, MassLynx™, and UNIFI™ software platforms.

---------------------------------------------------------------
Key Highlights

- High-resolution Quadrupole Time-of-Flight (QToF) mass spectrometer
- StepWave™ ion optics for enhanced sensitivity
- QuanTof™ detector technology
- Mass accuracy better than 1 ppm RMS
- Resolution >32,500 FWHM
- Mass range:
- TOF: m/z 20–100,000
- Quadrupole: m/z 20–4,000 (resolving mode)
- Supports MS, MS/MS, MSE®, and FastDDA
- IntelliStart™ automated calibration and diagnostics
- Compatible with ESI, APCI, ESCi®, NanoLockSpray™, APPI, ASAP, and APGC ion sources
- Fully compatible with Waters ACQUITY UPLC systems and MassLynx™ software
---------------------------------------------------------------

Applications / Uses

- Proteomics
- Metabolomics
- Biopharmaceutical characterization
- Intact protein analysis
- Peptide mapping
- Pharmaceutical R&D
- Impurity identification
- Food safety testing
- Environmental analysis
- Forensic toxicology
---------------------------------------------------------------

Typical Specifications (Summary)

- Mass Analyzer: Quadrupole Time-of-Flight (QToF)
- Mass Accuracy: <1 ppm RMS
- Resolution: >32,500 FWHM
- TOF Mass Range: m/z 20–100,000
- Quadrupole Mass Range: m/z 20–4,000 (resolving)
- Dynamic Range: ≥4 orders of magnitude
- Acquisition Modes: MS, MS/MS, MSE®, FastDDA
- Ion Sources: ESI, APCI, ESCi®, NanoLockSpray™, APPI, ASAP, APGC
- Software: MassLynx™, UNIFI™
- Power Requirements: 200–240 VAC, 50/60 Hz (site dependent)
---------------------------------------------------------------

Typical Configuration Includes

- Waters Xevo G2-S QTof mass spectrometer
- Vacuum system
- LockSpray™ ion source
- Roughing vacuum pump
- Source enclosure
- Instrument control workstation
- MassLynx™ software (if licensed)
- Power cablesShow moreShow lessClick to Request More Info