The PFT-1003CM(F) AC hipot test set provides continuously adjustable output voltages for overvoltage withstand testing of the following
Switchgear
Circuit Breakers
Reclosers
Vacuum Bottles
Hot Sticks
Motor Winding
Other High Voltage Insulations Requiring AC
Switchgear
Circuit Breakers
Reclosers
Vacuum Bottles
Hot Sticks
Motor Winding
Other High Voltage Insulations Requiring AC
Features
Continuously Adjustable Output Voltage
Fixed Overload, Factory Set to 120% of Rates Output Current
Zero Start and External Interlock Provision
Secondary Connected Dual-Range Voltmeter
Three-Range Current Meter with
Isolated Guard/Ground Return Circuit
Capacitive Transit Protected Meteres
Rugged Case with
Cushin Grips
Simple Controls
Continuously Adjustable Output Voltage
Fixed Overload, Factory Set to 120% of Rates Output Current
Zero Start and External Interlock Provision
Secondary Connected Dual-Range Voltmeter
Three-Range Current Meter with
Isolated Guard/Ground Return Circuit
Isolated Guard/Ground Return Circuit
Capacitive Transit Protected Meteres
Rugged Case with
Cushin Grips
Cushin Grips
Simple Controls
Specifications
Input
120 Volts
60 Hz
15 A
(F) 230 Volts, 50/60 Hz, 8 A
Output 0 - 100 kVA AC
1 kVA Resistive Load
3 kVA Capacitive Load
Up to 30 mA Current
Output Current is Reduced at lower Voltage Duty
3 kVA
1 Hour ON
1 Hour OFF
1.5 kVA
Continuous Voltmeter: 3.5in.
Scaled 0-50/100 kV AC
2% F.S Current Meter: 3.5in.
Scaled 0-10 mA
2% F.S with Range Multipliers of x1, x10, x1000 Distortion: Less than 5% size & Weight
Input
120 Volts
60 Hz
15 A
120 Volts
60 Hz
15 A
(F) 230 Volts, 50/60 Hz, 8 A
Output 0 - 100 kVA AC
1 kVA Resistive Load
Output 0 - 100 kVA AC
1 kVA Resistive Load
3 kVA Capacitive Load
Up to 30 mA Current
Output Current is Reduced at lower Voltage Duty
3 kVA
1 Hour ON
1 Hour OFF
3 kVA
1 Hour ON
1 Hour OFF
1.5 kVA
Continuous Voltmeter: 3.5in.
Scaled 0-50/100 kV AC
Continuous Voltmeter: 3.5in.
Scaled 0-50/100 kV AC
2% F.S Current Meter: 3.5in.
Scaled 0-10 mA
Scaled 0-10 mA
2% F.S with Range Multipliers of x1, x10, x1000 Distortion: Less than 5% size & Weight
(W x D x H) Case
21 x 11.25 x 15.25in.
35 lbs
534 x 286 x 387 mm
16 kg
21 x 11.25 x 15.25in.
35 lbs
35 lbs
534 x 286 x 387 mm
16 kg
16 kg
HV Tank
13 x 13 x 22 in.
85 lbs
330 x 330 x 559 mm
39 kg Options: The PFT-1003CM AC Hipot can be upgraded to include a fault burning circuit and a hand card is available to enhance portability
13 x 13 x 22 in.
85 lbs
85 lbs
330 x 330 x 559 mm
39 kg Options: The PFT-1003CM AC Hipot can be upgraded to include a fault burning circuit and a hand card is available to enhance portability
Location: Western Canada
View more Metering & Testing Equipment